Dalmierze dużego zasięgu

DL100-11AA2110

Zakres pomiarowy do 220 m (w zależności od modelu).

Parametry dla modelu DL100-11AA2110

Wydajność
Measuring range: 0,15 m … 60 m, On reflective tape “Diamond Grade”
Rozdzielczość: 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
Odtwarzalność: 1): 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms)
Accuracy 2): ± 3 mm
Nadajnik światła 3): Laser, red
Typ. light spot size (distance): 5 mm (+ 2 mm x distance in m)
Internal measurement cycle: 1 ms
Max. movement speed: 30 m/s
Klasa lasera: 2 (EN 60825-1 / CDRH)
Output time: Synchronous to PLC request (dependent on interfaces)
1) Statistical error 1 σ, environmental conditions constant, depending on operating mode  2) From 150 mm … 180 mm measuring range the accuracy can reach ± 4 mm  3) Average service life of 100,000 h at TA = +25 °C

 

Interfejsy
Data interface: EtherNet/IP
Switching output 1): B (push/pull)
MF1, MF2
Multifunctional input (MF) 2): 1 x MF1
1) HIGH > VS – 3 V / LOW < 2 V  2) HIGH > 12 V / LOW < 3 V

 

Mechanika/elektronika
Napięcie zasilania VS: DC 18 V … 30 V, limit values
Tętnienia resztkowe 1): 5 Vss
Initialization time 2): Typ. 1,5 s
Indication: 6 digit 5 x 7 dot matrix display, LEDs
Ciężar 3): Ca. 800 g … 1.600 g
Output current IA 4): ≤ 100 mA
Pobór prądu: At 24 V DC < 250 mA
Typ połączenia: Wtyk, M12, SPEEDCON™ compatible
Housing material: Aluminium
Modulation frequency: Fix
1) May not fall short of or exceed VS tolerances  2) After loss of reflector < 40 ms  3) Without mounting bracket: approx. 800 g, with mounting bracket: approx. 1,600 g  4) Short circuit/overload protected. Max. 100 nF / 20 mH

 

Dane otoczenia
Rodzaj zabezpieczenia: IP 65
Klasa ochronności: III
Effect of air pressure: 0,3 ppm/hPa
Effect of air temperature: 1 ppm/K
Dryft temperaturowy: Typ. 0,1 mm/K
Ambient temperature 1): Operation: -20 … +55 °C
Operation with cooling case: -20 … +75 °C
Storage: -40 … +75 °C
Mechanical load: Noise: EN 600 68-2-64
Shock: EN 600 68-2-27
Sine: EN 600 68-2-6
Kompatybilność elektromagnetyczna (EMC) 2): EN 61000-6-2 / EN 61000-6-4
1) Temperatures < -10 °C require warm-up time of typ. 7 minutes.  2) This is a Class A device. This device can cause radio interference in living quarters.