Zakres pomiarowy do 220 m (w zależności od modelu).
Parametry dla modelu DL100-11AA2110
Wydajność | |||
Measuring range: | 0,15 m … 60 m, On reflective tape “Diamond Grade” | ||
Rozdzielczość: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Odtwarzalność: 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Nadajnik światła 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Max. movement speed: | 30 m/s | ||
Klasa lasera: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) |
1) Statistical error 1 σ, environmental conditions constant, depending on operating mode 2) From 150 mm … 180 mm measuring range the accuracy can reach ± 4 mm 3) Average service life of 100,000 h at TA = +25 °C |
Interfejsy | |||
Data interface: | EtherNet/IP | ||
Switching output 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
1) HIGH > VS – 3 V / LOW < 2 V 2) HIGH > 12 V / LOW < 3 V |
Mechanika/elektronika | |||
Napięcie zasilania VS: | DC 18 V … 30 V, limit values | ||
Tętnienia resztkowe 1): | 5 Vss | ||
Initialization time 2): | Typ. 1,5 s | ||
Indication: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Ciężar 3): | Ca. 800 g … 1.600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Pobór prądu: | At 24 V DC < 250 mA | ||
Typ połączenia: | Wtyk, M12, SPEEDCON™ compatible | ||
Housing material: | Aluminium | ||
Modulation frequency: | Fix |
1) May not fall short of or exceed VS tolerances 2) After loss of reflector < 40 ms 3) Without mounting bracket: approx. 800 g, with mounting bracket: approx. 1,600 g 4) Short circuit/overload protected. Max. 100 nF / 20 mH |
Dane otoczenia | |||
Rodzaj zabezpieczenia: | IP 65 | ||
Klasa ochronności: | III | ||
Effect of air pressure: | 0,3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Dryft temperaturowy: | Typ. 0,1 mm/K | ||
Ambient temperature 1): | Operation: -20 … +55 °C Operation with cooling case: -20 … +75 °C Storage: -40 … +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Kompatybilność elektromagnetyczna (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
1) Temperatures < -10 °C require warm-up time of typ. 7 minutes. 2) This is a Class A device. This device can cause radio interference in living quarters. |